Geotechnical Indications of Bille Communnity in Niger Delta
component; deep foundation; bearing capacity; foundation failures; niger delta; settlement
Abstract
The study area which is situated Morphologically within the Salt Water / Mangrove swamp Zone, is underlain by thick volume of clay with low C u value of 14kpa and high Coefficient of Compressibility value. This results in large settlement observation and foundation failures of structures with high columns loads. Thus, Deep foundation is recommended for such structures. Soil Lithology reveals a medium dense Sandy layer (phi=>30) at an average depth >15m and Uniformity Coefficient indicating the sand as well graded. Pile load calculations indicates working loads < 300KN within diameter of 0.3m-0.45m at depths of 15m. Settlement calculations reveals expected settlement values of individual piles lower the allowable values.
Downloads
How to Cite
References
D Coduto (2007) Geotechnical Engineering: Principle and Practices.
V Murthy (2007) Soil Mechanics and Foundation Engineering.
H Nwankwoala, S Ngah (2014) Groundwater Resources of the Niger Delta: Quality Implications and Management Considerations. 5, 155-163.
H Nwankwoala, T Warmate (2014) Subsurface Soil Characterization of a Site for Infrastructural Development Purposes in D/Line, Port Harcourt, Nigeria. 4(6).
F Pacheco Silva (1970) An Evaluation of the Geotechnical Characteristics of the Abutments of a Proposed Bridge Across a 400-Meter River Channel in the Lower Niger Delta, Nigeria. 2.
G Alaminiokuma, J Osokpor, J Emudianughe, T Warmate (2016) Delineation of Soil Corrosivity Regimes Along Petroleum Pipeline Routes in the Geomorphic Zones of the Niger Delta using 2D Resistivity Tomography. 6(2), 5-15.
Published
2018-06-21
Issue
Section
License
Copyright (c) 2018 Authors and Global Journals Private Limited

This work is licensed under a Creative Commons Attribution 4.0 International License.