Dose Variation Profiles of Small Fields with a 10 MV Photon Beam
dose profile, radiotherapy, small fields, solid water phantom
Abstract
Radiotherapy is an important treatment form to care of patients with different types of cancer and improvement quality of life. Radiotherapy is a treatment of carcinogenic tumors using ionising radiation and the refinement of techniques in radiotherapy treatments are programmed to salvage of healthy tissues. The small dimensions in modern advanced radiotherapy treatments have employed in differents hospitals. These fields have differents characteristics for nonestablishment in the conditions to traditional dosimetry protocols. The obtained profiles permissible to check out disturbances in the exposures, considering the differences in the dosimetry of small fields and the impacts to local dose deposition. In this work, the dose distribution of an X-ray beam was recorded using a solid water phantom. This phantom was irradiated using small fields with 1×1, 2×2, 3×3 and 5×5 cm². The 10 MV X-ray beam was generated in a linear accelerator model Synergy Platform from the manufacturer Elekta and radiochromic film sheets were used to record dose profiles inside a solid water phantom.
Downloads
How to Cite
References
P Mourão, F De Oliveira (2018) Fundamentos de radiologia e imagem.
F Khan (2010) The physics of radiation therapy.
P Charles, S Crowe, T Kairn, R Knight, B Hill, J Kenny, C Langton, J Trapp (2014) The influence of Monte Carlo source parameters on detector design and dose perturbation in small field dosimetry. 489, 012006.
S Lam, D Bradley, M Khandaker (2021) Small-field radiotherapy photon beam output evaluation: Detectors reviewed. 178, 108950.
R Leão, R Sousa, A Oliveira, H Silva, A Mourão (2018) Validação de um modelo computacional de acelerador linear varian clinac 2100 utilizando o código egsnrc para utilização em dosimetria de pequenos campos. 6(1).
I Das, G Ding, A Ahnesjö (2008) Small fields: nonequilibrium radiation dosimetry. 35(1), 206-215.
Madelaine Tyler, Paul Liu, Christopher Lee, David Mckenzie, Natalka Suchowerska (2016) Small field detector correction factors: effects of the flattening filter for Elekta and Varian linear accelerators. 17(3), 223-235.
L Furnari (2009) Controle de qualidade em radioterapia. 3(1), 77-90.
R Júnior (2018) Avaliação das perturbações físicas de feixes de raios x em pequenos campos estáticos: uma abordagem teórica pelo método de monte carlo.
Edwin Sham, Jan Seuntjens, Slobodan Devic, Ervin Podgorsak (2008) Influence of focal spot on characteristics of very small diameter radiosurgical beams. 35(7Part1), 3317-3330.
(2017) Unknown Title.
Xinfeng Chen, Eric Paulson, Ergun Ahunbay, Aydin Sanli, Slade Klawikowski, X Li (2019) Measurement validation of treatment planning for a MR‐Linac. 20(7), 28-38.
S Webb (2015) Intensity-modulated radiation therapy.
M Mia, M Rahman, S Purohit, S Kabir, A Meaze (2019) Analysis of percentage depth dose for 6 and 15 mv photon energies of medical linear accelerator with cc13 ionization chamber. 28(1&2).
Y Tayalati, S Didi, M Zerfaoui, A Moussaa (2013) Monte carlo simulation of 6mv elekta synergy platform linac photon beam using gate/geant4.
M Aspradakis, J Byrne, H Pamans, J Conway, K Rosser, J War Rington (2010) Small field mv photon dosimetry. ipem report 103.
B Mijnheer (2017) Clinical 3D Dosimetry in Modern Radiation Therapy.
L Scaff (1997) Física da radioterapia.
Chris Constantinou, F Attix, Bhudatt Paliwal (1982) A solid water phantom material for radiotherapy x-ray and γ-ray beam calibrations. 9(3), 436-441.
Maegan Gargett, Adam Briggs, Jeremy Booth (2020) Water equivalence of a solid phantom material for radiation dosimetry applications. 14, 43-47.
Slobodan Devic (2011) Radiochromic film dosimetry: Past, present, and future. 27(3), 122-134.
Slobodan Devic, Nada Tomic, David Lewis (2016) Reference radiochromic film dosimetry: Review of technical aspects. 32(4), 541-556.
Azam Niroomand‐rad, Charles Blackwell, Bert Coursey, Kenneth Gall, James Galvin, William Mclaughlin, Ali Meigooni, Ravinder Nath, James Rodgers, Christopher Soares (1998) Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55. 25(11), 2093-2115.
S Aldelaijan, F Alzorkany, B Moftah, I Buzurovic, J Seuntjens, N Tomic, S Devic (2016) Use of a control film piece in radiochromic film dosimetry. 32(1), 202-207.
Maria Adad, Gabriela Hoff, Elaine Streck, Rochele Lykawka (2008) Curvas de isodose no ar em uma sala de mamografia. 41(4), 255-258.
Published
2023-12-09
Issue
Section
License
Copyright (c) 2023 Authors and Global Journals Private Limited

This work is licensed under a Creative Commons Attribution 4.0 International License.